Weidmüller 1067250000 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Bridge measuring transducer
Configuration DIP switch and button Linearity Typically ± 0.05 % of signal range Long-term drift 0.1 % / 10.000 h
Weidmüller 1175980000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 3-way isolator Power consumption, max. 0.8 W Power consumption, typ.
Weidmüller 1175990000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 3-way isolator Power consumption, max. 0.8 W Power consumption, typ.
Weidmüller 1176000000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA Setting parameters
Weidmüller 1176010000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal converters
Accuracy < 0.2 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA Setting parameters
Weidmüller 1176020000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Signal splitter
Accuracy < 0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters Input Configuration 0…20 mA (loop) Setting
Weidmüller 1176030000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Universal converter
Accuracy < 0.1 % of measuring range Configuration With FDT/DTM software Galvanic isolation 3-way isolator Power consumption, max. 1.2 W Power
Weidmüller 1176040000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption, max. 0.5 W Rail TS 35
Weidmüller 1176050000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.05 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption, max. 50 kByte Rail TS 35
Weidmüller 1176070000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.1 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption 30 mW per channel Rail
Weidmüller 1176080000 Analogue Signal Conditioning,Space-saving signal converter – ACT20M,Passive isolator
Accuracy < 0.1 % of measuring range Configuration none Galvanic isolation 2-way isolator Power consumption 30 mW per channel Rail
Weidmüller 1282490000 Analogue Signal Conditioning,Accessories,ACT20 (incl. DIN rail bus & powersupplies)
Degree of efficiency 100 % Rail TS 35, CH20M Bus Type of connection Screw connection Voltage supply 21.6…26.4 V DC