Weidmüller 7760054117 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Signal converters
Accuracy < 0.1 % of end value Configuration none Current consumption ≤60 mA (24V power supply, 20mA output) Galvanic isolation
Weidmüller 7760054119 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Passive isolator
Accuracy < 0.1 % of end value Configuration none Galvanic isolation 2-way isolator Rail TS 35 Step response time ≤
Weidmüller 7760054120 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P, Passive isolator
Accuracy < 0.1 % of end value Configuration none Galvanic isolation 2-way isolator Rail TS 35 Step response time ≤
Weidmüller 7760054121 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Passive isolator
Accuracy < 0.2 % of end value Configuration none Galvanic isolation 2-way isolator Rail TS 35 Step response time ≤
Weidmüller 7760054122 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Signal splitter
Accuracy < 0.1 % of end value Configuration none Galvanic isolation 3-way isolator Rail TS 35 Step response time ≤
Weidmüller 7760054123 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Passive isolator
Accuracy < 0.1 % of end value Configuration none Galvanic isolation 2-way isolator Rail TS 35 Step response time ≤
Weidmüller 7760054124 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Passive isolator
Accuracy < 0.1 % of end value Configuration none Galvanic isolation 2-way isolator Rail TS 35 Step response time ≤
Weidmüller 7760054164 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Measuring and monitoring relay
Accuracy 3 % *Urated voltage Configuration DIP switch and potentiometer Galvanic isolation 3-way isolator, between input ⁄ output ⁄ supply Measurement
Weidmüller 7760054165 Analogue Signal Conditioning,signal converter and process monitoring – ACT20P,Measuring and monitoring relay
Accuracy 3 % *Urated voltage Configuration DIP switch and potentiometer Galvanic isolation 2-way isolator, between input/output Measurement calibration max: 70…120% *Urated
Weidmüller 7760054175 Analogue Signal Conditioning,EPAK
Accuracy 0.15 % v. FSR Configuration none Galvanic isolation between input ⁄ output ⁄ supply Power consumption <60mA @ 24VDC
Weidmüller 7760054176 Analogue Signal Conditioning,EPAK
Accuracy 0.15 % v. FSR Configuration none Galvanic isolation between input ⁄ output ⁄ supply Power consumption <60mA @ 24VDC
Weidmüller 7760054177 Analogue Signal Conditioning,EPAK
Accuracy 0.15 % v. FSR Galvanic isolation between input ⁄ output ⁄ supply Power consumption <60mA @ 24VDC Step response